POWER ACCESS CORPORATION MODEL 4300 TECHNICAL INFORMATION last revised: 3-1-01 |
||
OPERATING & APPLICATION INSTRUCTIONS GENERAL For residential applications where the outside door usually opens in, the door mount model 4300D should be considered. The door mount opener is designed to be installed up side down at the top of the inside of the door (see fig. 2). With this application the opener is mounted on the inside of the door protected from vandalism and the elements. Note - for a door mount application be sure to check that the clearance behind the door, when it's open, is at least 8-1/2", thus permitting the door to open the full 90 degrees. An inverted jamb mount model 4300V is available for extra high doors where there is limited clearance above the door frame. The standard jamb mount application accommodates reveals from 1/2" to 4-1/2" (distance from the back of the door opener to the face of the door - see top view of drawing 4214). For applications where the reveal is greater than 4-1/2", but less than 9-1/2", the extended arm model 4300X is available. (see top view on drawing 4260). Whenever possible, the door opener should be mounted indoors to protect it from the elements and vandalism. When the door opener must be outside, it must be protected from the elements. If outside temperatures drop below freezing the low temperature model 4300LT should be specified. Left and right hand models are available - and the hand must be indicated when ordering. The hand is determined by standing on the "push" (non-swing) side of the door and observing on which side of the door the hinges are located - a door with hinges on the right requires a right hand door opener - a door with hinges on the left requires a left hand door opener. Door mount models are also handed from the push side even though they are installed on the pull side. The Model 4300 incorporates durable long life components for trouble-free, dependable service. The door opener has a number of important safety features - both electrical and mechanical. The door can be opened manually, independent of the opener, because the concealed, wheeled arm of the opener does not attach to the door. A built-in safety circuit senses load changes and automatically stops the door in the event it meets an obstruction while opening. After timing out, the arm will automatically retract. The safety circuit potentiometer needs to be adjusted for each application. For additional protection, there is an externally mounted circuit breaker (3 ampere) as well as a thermally protected drive motor. Since the opener arm does not attach to the door, a door closing device is required; such as, a concealed or surface mounted door closer - or, in some special cases, spring hinges. If a surface closer is used it must be on the opposite side of the door from the opener. (The LCN Super Smoothe¨ series is an excellent closer for outdoor applications, particularly where below zero winter temperatures may occur.)
APPLICATION A. Geometry - The opener must be mounted in the correct relationship to the door hinge. When the door is in the open position, the opener is located laterally so that the door is open 90 degrees. If the opener is laterally too far from the hinge point, less than a 90 degree opening will occur. If it is too close to the hinge point, a greater than a 90 degree opening will occur. If the opener is mounted too far from the face of the door, there may not be enough mechanical force to fully open the door. (See drawings 4214 and 4260). Drawing 4214 - Illustrates the typical application of a hinge hung door where the jambs are 4-1/2" wide to 7-1/2" wide. The reveal (distance from the back of the door opener to the face of the door) should not exceed 4-1/2". For reveals greater than 4-1/2," but less than 9-1/2", you may use the "deep reveal" model. Drawing 4260 - Illustrates a deep reveal application for dimensions between 4-1/2" and 9-1/2" Drawing 4261 - Illustrates the application of an inverted door opener. No clearance is required above the top of the jamb, but this arrangement is not recommended for standard height doors because the door opening clearance would be reduced by about 9 inches. Drawing 4262 - Illustrates an application with a shallow reveal that uses the P/N 4531 shallow reveal mounting bracket to provide a mounting surface for the opener. Drawing 4264 - Illustrates the positioning of the opener with respect to the door pivot and off-set hinged doors. It also shows how to determine lateral location for any application. Drawing 4269 - Illustrates a door mount application (typical of a residential front door) where the opener must be on the "pull" side of the door with the arm rolling against the top of the jamb. Minimum side clearance of 8-1/2" (i.e. the clearance behind the opened door) is required so that the opener may be located close to the hinge point to permit the door to open to 90 degrees. Drawing 4265D - Illustrates the wiring to the printed circuit board, including proper control hookup. Also shown is the internal wiring to the various components. Glass doors do not present a problem except in the case where the upper rail of the door is so narrow as to cause the roller to bear directly on the glass. In this case, the scuff plate P/N 5616NH (bearing plate) should be affixed to the top of the door. B. Opening Forces at the start of the cycle can be adjusted to exert about 60-80 pounds of force on the latch edge of the door. As the door opens, the mechanical advantage steadily decreases as the roller moves across the face of the door - to about 15 - 20 pounds at the latch edge when the door is open. Door forces can be measured with a spring scale to determine if they exceed the capability of the C. The Model 4300 has been designed for use primarily on low traffic, secondary doors. It can also be used on many entrance doors, but because of its design and slower opening speed, (7-8 seconds) the Model 4300 is not suitable, and should not be used, for high traffic rate applications where all traffic or high rates of traffic would be using the door automation. Most entrance doors being considered, are to be automated to provide accessibility for handicapped, elderly or burdened individuals. Steps should be taken to limit use to these individuals and have the general pedestrian traffic use the door manually. This can be best be done by locating controls (wall or post) slightly out of the mainstream of traffic, or providing radio control to specified users.
.D. Controls - Several types of controls are available in wired and/or wireless modes. The most commonly used control is the wireless push/plate. When using wireless controls with the Model 4300 series opener a 4470 receiver must also be ordered. In addition to wall mounted controls (surface or flush), there are post mounted, hand held, keyless programmable, sip and puff, ECU interface and others to meet specific user needs. E. Electric Strikes - are used when the door being automated has a latch or deadbolt that will be used to secure the door. A strike is installed in the door frame, lined up with the latch or deadbolt. Strikes are wired to the door opener. When the opener receives a signal to open the door, it automatically unlocks the door. F. Door closing devices - The 4300 opener is used in conjunction with independent door closers. Some doors in commercial buildings have concealed closers, however most closers are the surface mounted type which frequently have to be relocated or changed. Power Access carries a selection of LCN closers to meet most needs.
JAMB MOUNT MODEL 4300 A. Prop the door in the open position - usually a little over 90 degrees - to allow for compression of the roller and play in the linkage. B. Cycle the door opener so that the arm of the opener is in the full open position - about 105 degrees. This is done by removing cover, supplying temporary power to door opener and giving the door opener an operate signal across the low voltage terminals marked :"SW IN" WHT and BLK, or if door opener is setup with a receiver, give it a signal with a wireless control. Turn toggle switch to off and disconnect the power when the arm is in the full open position.
C. Install slide mounting bracket to upper part of the jamb (hinge side) with (2) #10 1-1/2" sheet metal screws provided. Next, slide door opener onto slide mounting bracket until arm roller is snug against the propped open door. Install the remaining (3) #10 1-1/2" sheet metal screws through appropriate holes in opener frame into underside of door frame header. If doorframe is metal it is suggested that hole locations be marked with door opener on the bracket, then remove unit, drill pilot holes and again slide door opener onto bracket and secure with the sheet metal screws. In some cases "riv" nuts should be used with metal frame to assure a stable installation. D. Install stainless steel scuff plate on door with the #8 x 1/2" sheet metal screws provided - as shown in figure 3. Manually open door to be sure it opens to desired location (usually slightly more than 90 degrees) and moves freely. If the door binds, plane where necessary or shim the hinges. In the case of a heavy door with old hinges, replace with ball bearing type. E. If necessary replace the latch strike plate with the blank plate provided. If security is required, an electric strike may be interfaced with the opener control circuit. F. When using wall switches or touch controls, drill a small hole in the jamb or wall near the point where the power cord from the unit is located - and a small hole through the G. Thought should be given to control location to achieve desired objectives. In order to reduce usage of the opener to only those needing it, the controls should be located slightly out of the general traffic path. Wall mounted controls must be mounted so that the door to be powered is visible from the control location. Wireless Wall Controls simplify the installation because interconnecting wiring is not necessary. H. Electrical hook up can now be completed. Drawing 4265D illustrates the necessary wiring information. Be sure that the opener is provided with a 115 VAC grounded outlet - or hard wired in accordance with local codes. Note - for applications when the door opener is located on the outside of a door in a public area and it is to be interfaced with an electric lock, the on/off switch should be disconnected and the door opener should be hard wired. I. When power is first turned on you will hear unit cycle once. There are only two field adjustments on the unit printed circuit board. First is the "time hold open" (see step 2 ) and the second adjustment is for sensitivity (see step 3). This safety feature is to stop the arm from opening the door when the door hits an obstruction on the opening cycle. The unit is now ready to be tested and adjusted. 1. Signal for door opener to open - (opening cycle takes about seven seconds). 2. Set the "time hold open" potentiometer to desired time (0-30 seconds - clockwise for more time). See drawing 4265D. Door opener comes preset with approximately a 7 second hold open. Note - the electronic timer which governs the hold open time starts its timing cycle when the opening cycle begins - thus a 7 second hold open, is in addition to the 7 second opening time for a total of 14 seconds. 3. Set the load sensitivity adjustment to the proper position for the particular application. (The location of the sensitivity potentiometer is on the circuit board next to the transformer - see drawing 4265D). By turning the small brass screw counterclockwise to the minimum setting you will be at the most sensitive setting (door probably won't open). Turn the screw clockwise in increments until the door achieves a full open position. The door should be manually stopped during opening cycle to be sure the motor stops and recycles to the closed position. Note: the load sensitivity potentiometer has an adjustment range of 24 turns and a clicking sound will be heard at either end of the range. 4. If a safety carpet is being used, hook the carpet leads to the inhibit (INH) terminals and check its operation with the door opener. If someone is on the carpet the door will not open or close depending on the door position. If the door is moving and someone steps on the carpet and remains on it, the door will complete the cycle and then will be inoperative until the safety mat is cleared. These inhibit terminals can also be used to interface with an elevator or lift safety circuitry. 5. The Model 4300 can be interfaced with an electric strike system: The strike output from the P.C. board is 115 VAC and is powered on the opening and closing cycle. Transformers for a variety of strike requirements are available and can be factory mounted in the door opener. They come with a 10 foot, 2 wire lead to power the strike - either AC or DC. (AC strikes emit a buzz when operating while DC strikes are silent.) 6. Two or more door openers may be hooked up to be used simultaneously from one input by wiring the black and white switch terminals in parallel. In the case of radio control output, one receiver can be used with the door openers wired as above. Note - when two or more door opener units with radio controls J. Reinstall cover by means of (2) hex head screws securely tightened to avoid vibration noise. DOOR MOUNT MODEL 4300D For a door mount installation, the following installation steps should be followed: 2. Install the #4590 door mount bracket that comes with each door mount unit. The 2" x 2" angle bracket is mounted to the face of the door - 1" down from the top of the door and ¸" in from the hinge side of the door. (see drawing #4269). The leg that mounts to the door has three round holes (9/32nd) and the horizontal leg has the slotted holes.
4. The door opener is secured to the bracket using the slotted holes to allow for some adjustment. See drawing #4269. It may be necessary to drill new holes on the bracket or extend the slotted holes depending on unusual casing that might be around the frame. "C" clamps or vise grips are handy for temporarily securing the door opener to the bracket while installing the hardware provided. 5. Note - in installations where there is clearance behind the door for the door opener, but a very tight space to work, it is suggested that after the bracket has been properly mounted, i.e. holes located and drilled on the door, remove the bracket. Attach the door opener to the bracket with the hardware provided; and with the arm in a closed position, mount the assembly to the door with the through bolts provided. A stubby screw driver or a right angle ratchet would be helpful. 6. The door arm roller will roll against the casing of the door jamb and push the door away from the frame to the full 90 degrees. Note - the door mount arm opens to about 112 degrees - 7 degrees more than the standard jamb mount door arm which opens to 105 degrees. 7. Be sure to provide a strain loop on the power cord coming out of the door opener so as to reduce wire fatigue from the cord flexing as door opens and closes. Follow the above steps "E" through "J" to complete the installation. MAINTENANCE |